Cooling water disinfection – keeping Legionella and biofilms under control

Cooling water circuits, cooling towers, and evaporative cooling systems are high-risk areas for microbial growth: warm temperatures, aerosols, and organic contaminants create ideal conditions for Legionella, biofilms, and other pathogens. Uncontrolled microbial growth not only endangers the health of employees and nearby residents, but also leads to reduced efficiency of the cooling systems, increased energy consumption, and corrosion damage.

The 42nd BImSchV stipulates clear limit values, regular sampling, and comprehensive documentation for operators of cooling towers and evaporative cooling systems—with substantial fines for violations.

INNOWATECH Anolyte® keeps cooling water circuits permanently aseptic—it contains few hazardous substances, is safe for materials, and is fully compliant with the 42nd BImSchV.

Challenges

Cooling water: an underestimated risk with far-reaching consequences.

Legionella bacteria in cooling towers can be spread over long distances via aerosols and cause severe lung diseases—even in people who are near the facility. Fatal Legionella outbreaks caused by contaminated cooling towers in the past have shown just how seriously this risk must be taken.

At the same time, biofilms form rapidly in cooling water circuits, protecting microorganisms from disinfectants, causing heat exchangers to become clogged, and significantly reducing the efficiency of the entire cooling system. Conventional biocides are often associated with hazardous substance issues, corrode system components, or leave behind undesirable residues.

Solution

INNOWATECH Anolyte® – long-lasting effectiveness, gentle on materials, compliant with standards.

INNOWATECH Anolyte®

INNOWATECH Anolyte® is continuously dosed into the cooling water circuit and is highly efficient in combating Legionella, biofilms, and other pathogens—without acids or lye, without the risk of corrosion, and without damaging gaskets and elastomers.

The high hocl content—over 80%—ensures a powerful disinfecting effect even at very low concentrations. Biofilms are broken down and prevented from reforming—which not only protects health but also safeguards the efficiency and service life of the refrigeration system.

INNOWATECH Multi-Measurement Center

The INNOWATECH Multi-Measurement Center continuously monitors all relevant parameters—free chlorine, ph, temperature, conductivity, and redox—and records them fully automatically. This enables operators to fully comply with the documentation requirements of the 42nd BImSchV without any additional effort.

Advantages

Compelling advantages

Reliable protection against Legionella

Also in cooling towers and evaporative cooling systems

Biofilm removal and prevention

Protects heat exchangers and system components

In compliance with 42. BImSchV

Complete documentation included

Compatible with materials

No risk of corrosion, no damage to elastomers

Water, table salt, and electricity

No transport of hazardous materials, no secure storage facility

Energy efficiency

Clean heat exchangers operate more efficiently

Fully automatic

Minimal staffing requirements, maximum operational reliability

FAQ

Frequently asked questions about cooling water disinfection

Cooling water circuits, cooling towers, and evaporative cooling systems are potential breeding grounds for Legionella and other pathogens. Germs can enter the ambient air via aerosols and be inhaled—with potentially life-threatening consequences. The 42nd federal immission control ordinance (42. BImSchV) therefore requires operators to implement a hygiene plan, conduct regular water testing, and maintain complete documentation.

INNOWATECH Anolyte® is highly efficient against all relevant pathogens in cooling water circuits—including Legionella pneumophila, pseudomonas aeruginosa, E. Coli, coliforms, and other microorganisms that pose a threat to water quality. In addition, it breaks down biofilms and prevents their regrowth—a key advantage over many conventional biocides.

Conventional cooling water biocides are often classified as hazardous substances and require complex handling procedures, protective equipment, and special storage conditions. Many also leave residues in effluent and harm the environment. INNOWATECH Anolyte® is produced on-site from water and table salt—without the need to transport hazardous substances, without the need for secure storage, and without environmentally harmful residues. At the same time, it is highly efficient against germs and biofilms and is gentle on materials.

Biofilms are one of the biggest challenges in cooling water systems: they protect microorganisms from disinfectants and allow for continuous recontamination of the system. INNOWATECH Anolyte® penetrates the biofilm structure, destroys the protective matrix, and reliably eliminates the microorganisms it contains. At the same time, it prevents the formation of new biofilms—ensuring permanently clean cooling circuits.

Yes. INNOWATECH Anolyte® is ph-neutral and does not pose an increased risk of corrosion. It is compatible with all common materials used in cooling circuits—including steel, stainless steel, copper, plastics, and elastomers. No extensive material protection or special measures are required.

The INNOWATECH Multi-Measurement Center automatically and continuously records and documents all relevant water parameters—free chlorine, ph, temperature, conductivity, and redox. The measurement data is stored in its entirety and can be retrieved at any time for regulatory inspections. This completely eliminates the need for manual documentation.

If the Legionella count exceeds 1,000 CFU/100 ml, the 42nd BImSchV mandates immediate action—including shutting down the system. In such cases, INNOWATECH Anolyte® enables rapid shock disinfection, which can eliminate contamination within a short period of time. The INNOWATECH Multi-Measurement Center automatically alerts the responsible staff when limit values are exceeded.

Yes. The INNOWATECH Aquadron® is designed as a compact system and can be integrated into existing cooling water systems with minimal installation effort—regardless of system size or manufacturer. INNOWATECH provides planning, installation, and commissioning services all under one roof.

Yes. INNOWATECH systems are custom-designed to meet the specific requirements of each facility—from small closed cooling circuits to large open cooling towers with high water volumes. Dosage is controlled fully automatically according to demand.

Operating costs are minimal: the only consumables required are water, table salt, and electricity. Compared to the ongoing purchase of conventional cooling water biocides—including storage, handling, and disposal costs—this generally results in significant cost savings, along with greater operational reliability and better documentation.

Contact

Questions? We’re happy to help!

    *Required