Legionella, pseudomonas, and others—reliably eliminated.
Legionella, pseudomonas aeruginosa, E. Coli, and elevated total bacterial counts in a building’s drinking water system are a serious and often underestimated problem. They multiply unnoticed in hot and cold water systems, in dead-end pipes, fittings, and showerheads—and can lead to serious illnesses.
For building operators, this poses not only a health risk to occupants but also significant liability risks and costly remediation efforts. INNOWATECH Anolyte® combats these germs highly efficiently and permanently—even in places where conventional methods, such as thermal disinfection, reach their limits.

Challenges
When drinking water becomes a hazard.
Drinking water systems in buildings provide ideal conditions for germs: dead-end pipes with stagnant water, temperatures ranging from 25 °C to 50 °C, and biofilms acting as a protective layer—all of which promote the growth of Legionella and other pathogens.
A particularly critical issue: modern energy systems such as heat pumps and low-temperature heating systems often operate hot-water systems at temperatures below 60 °C—the traditional threshold for thermal Legionella control. Conventional measures are no longer reliable in this context.
At the same time, Legionella and pseudomonas can also multiply in cold-water systems if temperatures rise above 20 °C due to sunlight, inadequate insulation, or long periods of inactivity.
Solution
INNOWATECH Anolyte® – long-lasting germ protection for hot and cold water.
INNOWATECH Anolyte® is continuously dosed into the drinking water system and ensures long-lasting, reliable disinfection—regardless of the operating temperature. With a high hocl content of over 80%, Anolyte® is highly efficient against Legionella, pseudomonas, E. Coli, and other pathogens even at very low concentrations.
Crucially, INNOWATECH Anolyte® breaks down biofilms—the protective coating in which Legionella and other pathogens hide from disinfectants—and permanently prevents their regrowth.
Hot water systems:
Long-lasting protection against Legionella even at operating temperatures below 60 °C—ideal for heat pumps, solar thermal systems, and other renewable energy systems. INNOWATECH Anolyte® fills the gap left by thermal measures in modern building systems.
Chilled water systems:
Reliable microbial reduction and biofilm control, even at low temperatures. Legionella, pseudomonas, and elevated total microbial counts are consistently kept below legal limits.

Advantages
Compelling advantages
Highly efficient
Against Legionella, pseudomonas, E. Coli, total bacterial count
Biofilm degradation
Removes biofilms and prevents their regrowth
Effective at temperatures below 60 °C
Compatible with heat pumps and low-temperature systems
For hot and cold water
Comprehensive protection for the entire building system
Compatible with materials
No risk of corrosion, no damage to elastomers
Water, table salt, and electricity
Safe for residents, users, and service staff
Fully automatic
Minimal effort, maximum operational reliability
FAQ
Frequently asked questions about drinking water contamination in building plumbing systems
Microbiological contamination in a building’s drinking water system occurs when pathogens such as Legionella, pseudomonas aeruginosa, E. Coli, or other microorganisms multiply in a building’s drinking water pipes, fittings, storage tanks, or dead-end pipes and compromise the quality of the drinking water. This often goes unnoticed—until a routine inspection or an illness reveals the contamination.
The most common and dangerous pathogens in drinking water systems within buildings are:
- Legionella pneumophila – the pathogen that causes legionnaires' disease, a severe form of pneumonia
- Pseudomonas aeruginosa – particularly dangerous for immunocompromised individuals
- Escherichia coli (E. Coli) – an indicator of fecal contamination
- Enterococci – an indicator of hygiene deficiencies in the system
- Elevated total bacterial count—indicative of general hygiene deficiencies and biofilm formation
Legionella bacteria multiply most effectively at water temperatures between 25 °C and 50 °C—a range that is commonly found in many buildings, such as in hot-water storage tanks that are not heated sufficiently, in dead-end pipes with stagnant water, or in modern low-temperature systems with heat pumps. Biofilms in pipes and fittings provide Legionella bacteria with additional protection against disinfection measures and allow for continuous recontamination of the system.
Operators of drinking water systems in commercial buildings—including residential buildings with more than two residential units, hotels, hospitals, nursing homes, schools, sports facilities, and office buildings—are required under the drinking water ordinance (TrinkwV) to regularly monitor drinking water quality and to take immediate action if limit values are exceeded. For Legionella, the technical action level is 100 CFU/100 ml.
Untreated Legionella contamination can have serious consequences: building occupants are at risk of legionnaires’ disease—a severe, potentially life-threatening form of pneumonia. Operators face regulatory requirements, usage bans, fines, and civil liability claims. In addition, costly remediation measures and operational disruptions can cause significant economic damage.
Traditional thermal disinfection—regularly heating hot water to at least 70 °C—is often technically impossible or economically unfeasible in modern heat pump and low-temperature systems. These systems are deliberately designed to operate at low temperatures to save energy—but in doing so, they create ideal conditions for the growth of Legionella. INNOWATECH Anolyte® reliably bridges this gap: it is highly efficient even at operating temperatures below 60 °C.
INNOWATECH Anolyte® is automatically dosed into the drinking water system and is highly efficient in combating Legionella, pseudomonas, E. Coli, and other pathogens—thanks to its high hocl content of over 80%, it is effective even at very low concentrations. Biofilms in pipes, fittings, and storage tanks are broken down and prevented from reforming—thereby permanently depriving germs of their means of survival.
Yes. Cold-water systems are also at risk—especially when the water temperature rises above 20 °C due to external factors such as sunlight or thermal bridges. INNOWATECH Anolyte® reliably combats Legionella, pseudomonas, and other pathogens even in cold-water systems—and prevents biofilm formation, which is particularly common in cold-water pipes.
Yes. INNOWATECH Anolyte® is ph-neutral and does not pose an increased risk of corrosion. It is compatible with all common materials used in drinking water systems—including copper, stainless steel, galvanized steel, plastics, and elastomers. Existing systems can be treated with INNOWATECH Anolyte® without the need for extensive renovation work or material replacement.
The INNOWATECH Aquadron® produces INNOWATECH Anolyte® fully automatically on-site and dispenses it precisely into the drinking water system. The system is designed as a compact unit and can be integrated into existing building systems with minimal installation effort—in the basement, in the utility room, or directly at the service connection. INNOWATECH handles planning, installation, and commissioning as a one-stop solution.
The INNOWATECH Multi-Measurement Center automatically and continuously records and documents all relevant parameters—free chlorine, ph, temperature, conductivity, and redox. The measurement data is stored in its entirety and can be retrieved at any time for regulatory inspections, risk assessments in accordance with the drinking water ordinance (TrinkwV), and documentation for the public health department.
A shock disinfection is a one-time, high-dose treatment of the drinking water system designed to quickly eliminate acute contamination—for example, after Legionella bacteria have been detected. It eliminates the bacteria in the short term but does not prevent recontamination. Continuous disinfection with INNOWATECH Anolyte®, on the other hand, provides ongoing protection for the system—it prevents the formation of new biofilms and keeps bacteria levels permanently below legal limits.
The INNOWATECH solution is suitable for all types of buildings with drinking water systems—including apartment buildings, hotels, hospitals, nursing homes, schools, sports arenas, office buildings, industrial facilities, and public institutions. The system is custom-designed to meet the size and requirements of each specific installation.
Operating costs are minimal: the only consumables required are water, table salt, and electricity. Compared to recurring thermal disinfection, manual rinsing procedures, or the purchase of conventional disinfectants, this generally results in significant cost savings—while simultaneously ensuring consistently higher drinking water safety and comprehensive documentation.